We are providing this Technical Note to inform you about the release of BIOVIA Compose and Capture 2023 which includes the following enhancements and fixed defects:

Enhancements

This release of BIOVIA Compose and Capture includes the following enhancements.

User Story

Description

CAPT-3310

Capture Hub users can now export the contents of the Material card.

CAPT-6393

Added two toggles:

·         # System-level toggle: "Enable Automated Review by Exception"

·         # System-level toggle: "Enable Observation as an Exception"

CAPT-6495

Tasks used to generate materials used during a Capture session are presented in the "Related Tasks" field in Review and report.

CAPT-6769

When initiating batch making, the system enforces ingredient tolerances defined on the formula. 

CAPT-6988

Users can hide, size, and reorder the columns in the Capture parameters grid in horizontal view.

CAPT-6999

The related material tasks, metrology tasks, and linked tasks are sorted in the review and report.

CAPT-7119

Modified the signature handling for Procedure tasks to show when an action is pending a second signature.

PROP-10280

In Compose when the sample is added to a step, from the Parameters tab, the author can add parameters mapped with the sample.

PROP-10408

In Compose, when the material is added to a step and the scan container/register batch is checked, from the Parameter tab, the author can add parameters mapped with the Material.

PROP-10696

Recipes can be configured to use Lifecycle Policy signatures rather than Compose signatures. The flag can be found under Admin and Settings > Applications > Application Settings > Foundation Hub > Process Execution > Recipes, governed by Lifecycle Policy signature settings:

·         Yes:  Recipes will always be governed by Life Cycle Policy

·         No:  Enables a "Use Lifecycle Signatures" check box during Capture Hub recipe creation/cloning.

CAPT-3345

Capture Hub no longer uses the signature policies as defined by the Author in Compose. Instead, Capture Hub execution inherits the Lifecycle Policy from the task and the signature policies therein.

CAPT-3664

In Capture Hub execution, all DateTime parameters display the date in the current format, and time displays in HH:MM:SS.  

CAPT-7293

For Data Acquisition tasks, when the Data Preview page loads, it shows all File/Adapter equipment that has at least one data field that matches an activity parameter equipment reading mapping in the current task.

CAPT-6822

When a material amount parameter is collected during execution, the material in the Capture material list is updated to reflect this amount. The unit is from the very first value collected.

CAPT-6394

Upon completion, a task is automatically Reviewed, and if no blocking exceptions are present, the task is automatically Released.

Fixed Defects

This release of BIOVIA Compose and Capture includes the following fixed defects.

Defect

Description

CAPT-7033

Since 2022 SP1, an issue has been fixed in which the branch activation failed due to improper evaluation of numeric values.

CAPT-7036

Since 2022 SP1, Numeric parameters formatted as Decimal 0 are correctly formatted when their actual expression evaluates to 0. If 0 is out-of-limits, it is correctly flagged and can trigger an OOL signature.

CAPT-7039

Since 2022 SP1, classic Capture Review and Report display saved vocabulary entries even if there are more than 100 category ‘Compose’ vocabularies in the system.

CAPT-7388

Classic Capture now searches the first 1000 material synonyms when looking for a specific recipe synonym during scan container.

PROP-10716

In Recipe Materials, when tolerances are edited from raw to min/max to threshold, previous values are not cleared. Tolerances are now removed properly and the UI now displays the correct tolerance.

PROP-10743

The parameter display name is now updated as follows:

·         If the material and mapped Amount have been added, the display name is “Material Name Amount”.

·         Then edit that to “Material Name Volume”.

·         Then if the material is removed the parameter name becomes “Volume”.

This approach correctly reflects that the parameter is no longer associated with any material, but it also persists in any edits.

CAPT-6790

Expressions with compound quantities have been normalized and now show the proper numeric value.

CAPT-7017

An Expression converting "Delta Temperature / Time -> Temperature Per Time" is now calculated correctly.

CAPT-7082

Expressions with complex unit multiplications or divisions now work as expected in Capture Hub.

CAPT-7163

Updated behavior to not flag materials as expired if they were not triggering a Material Expiration signature event at the time of use.  

CAPT-7255

When scanning a barcode results in Material Warnings being shown, clicking Cancel no longer presents the user with a redundant warning message.

CAPT-7290

Form view shows the correct unit for the sample mapped parameter value, even when the planned value unit is changed in the Task Plan.

CAPT-7292

Capture Hub supports mapping of Text recipe parameters to sample extended properties of Vocabulary type.

CAPT-7313

Statistical functions that take multiple optional parameters as arguments work as expected. For example, expression sum(parameter("1-a", "actual"), parameter("1-b", "actual"), parameter("1-c", "actual")) will produce a result even if only parameter 1-c has a value.

PROP-10506

Compose now provides a parameterized GET that updates changes to phrasing made by utilizing the API.

PROP-10685

The second 'select' statement in an "nthSelect" expression is now correctly updated when parameter steps are moved to a different location.

PROP-10688

Fixed an issue in which, under specific conditions in certain recipes, Compose's Process Element Parameters were sharing a rootId.

PROP-10733

 The Install log is now in the proper format (UTF-8) and is readable.

 

PROP-10783

When transitioning a recipe to a workflow state that requires a signature, the signer will have to provide a 'Reason Code' if the Signature Policy requires it.

PROP-10810

The default LifeCyclePolicy from CollabSpace is now updated for an Activity published from a recipe.

CAPT-6668

Applied the following rules to calculate RAW values when assigning calculated values to parameters, Capture Hub now applies the round-off rules below:

·         round to 15 digits

·         when the result is larger than 15 digits (>= 1e+16), keep more than 15 digits

·         when the result is less than 1, including leading zeros as digits (e.g. 0.0123 is 5 digits, not 3 digits)

·         when the result is less than 1e-12, turns to ZERO value

CAPT-6701

The performance of the "Clear All" function was significantly improved.

CAPT-7007

In the Step Instructions a planned expression using concat on two cleared Text values will now display 'Pending Calculation'.

CAPT-7074

The View Measurement button now displays all of the measurements used during the execution lifecycle, not just those that are currently used/active.

CAPT-7080

The footer navigation bar no longer overlaps the steps panel in Review.

CAPT-7098

"Right-click + Copy" works for single row/column and multiple row/column (select all) in Capture horizontal grid view.

 

CAPT-7112

Generic error messages are provided in Capture when retrieving values from Integration Gateway equipment having connection issues.

CAPT-7166

Classic Capture Review no longer crashes in the rare scenario where an empty observation with no text was saved.

CAPT-7343

The Sample Creation protocol is included as an example protocol.

PROP-10651

Compose recipes can now be imported successfully into an environment when more than1250 vocabulary entries exist.

PROP-10664

Fixed an issue when under certain circumstances, the Compose Parameters UI becomes unusable.

PROP-10680

Fixed an issue where in some cases, when an image is embedded in a recipe, the Save button was enabled even when no changes were made to the recipe.  

PROP-10713

Unit selection persists when parameters are upgraded and renamed.

PROP-10762

Equipment mappings persist when duplicate recipe equipment is added and removed from the equipment section.

PROP-10771

Compose no longer updates Material and Equipment mapped parameter disposition from 'Material Charge' to 'Reference.'

PROP-10777

When upgrading parameters with new parameter templates version parameter template names are updated correctly in recipes that have been published as activities.

PROP-10787

An embedded image is now shown properly in the Capture instruction.   

 

PROP-10789

When there is a new version of the parameter template available, fixed the issue during upgrading the unit-less quantity parameter with the latest version of the parameter template. 

PROP-10805

The Expression Editor dialog now opens centered in the browser window, even when other parameters are added to a step that contains many parameters.

PROP-10807

Updated the report version shown in the footer to 2023.1.0.

CAPT-5411

In Capture, the equipment barcode input field and sample context menu now automatically close on a view change.

CAPT-6753

The raw division of very large numbers that are results of other calculations is now more precise.

CAPT-7181

Fixed an issue when during lifecycle transitions in Capture, a localization string name was getting displayed in the lifecycle drop-up.

PROP-10712

In the Compose process step Activities tab column, the 'Method Id' name has been updated to 'Method ID'.

Resolution                                                                         

BIOVIA Compose and Capture 2023 was released on 12 December 2022 and is available for download at https://software.3ds.com under BIOVIA products:

Product line: Lab, Scientific and Content Solutions

Release: BIOVIA 2023

Level: BIOVIA 2023 Golden

Fixes for this level: N/A