T64-2020 Notification regarding BIOVIA Pipeline Pilot 2018 SP1 HF2
BIOVIA Pipeline Pilot 2018 SP1
Program
BIOVIA Pipeline Pilot 2018 SP1
Operating System
All operating systems supported for BIOVIA Pipeline Pilot 2018 SP1
Description
We are providing this Technical Note to inform you of the release of BIOVIA Pipeline Pilot 2018 SP1 HF2. It includes the following fixed issues:
PCHE-7404- Enumerate Stereoisomers previously produced a “Cannot dereference a NULL pointer” in “Represented Stereo Only” mode. This occurred when the number of stereoisomers is larger than the threshold set using the “MaximumNumberOfStereoisomers” parameter. This has now been fixed.
PCHE-7406 - A problem perceiving aromaticity of six-member rings with alternating single and double bonds and high-valent atoms such as sulfur has been corrected in this release. The aromaticity will be perceived the same regardless of the position of the alternating double bonds.
PCHE-7415 - Added check for sp3 hybridization to consider constrained Nitrogen atoms as potential stereo centers. Now sp2 Nitrogens will never be perceived as stereo.
PCHE-7405 - The Standardize Molecule component was incorrectly assigning double bond stereo to S=N bonds in small rings (ring size less than 7). These assignments caused problems in the CIP calculations.
Resolution
BIOVIA released Pipeline Pilot 2018 SP1 HF2 in June 2018. It is available by contacting BIOVIA Support.
BIOVIA Support
If you have any questions, please contact BIOVIA Support.