BIOVIA Workbook experiments may not open after applying updates to the Microsoft Windows 10 operating system. Workbook displays the following error.
Resolution:
You can resolve this issue by either repairing or re-installing Microsoft Visual J# 2.0 Redistributable Package - SE (x64). So far, there has been no need to repair or re-install BIOVIA Workbook.

BIOVIA recommends that you apply the updates for the Microsoft Windows 10 operating system for a few Workbook Client machines, and then, check that Workbook Client functions correctly. This will enable you to determine if your environment will require a repair/re-install of Microsoft Visual J# 2.0 SE, before deploying the Microsoft Updates to all machines.

For questions regarding BIOVIA applications, please contact BIOVIA Support.
Error Mesage:
Symyx.Framework.Vault.Exceptions.VaultException: An unexpected error occurred while retrieving vault objects ---> System.TypeInitializationException: The type initializer for 'java.lang.System' threw an exception. ---> java.lang.UnsatisfiedLinkError: Unable to load DLL 'vjsnativ': The specified module could not be found. (Exception from HRESULT: 0x8007007E)

--- End of inner exception stack trace ---

at java.lang.System.getSecurityManager()

at java.io.File.getCanonicalPath()

at java.io.FileInputStream..ctor(File file)

at java.io.FileInputStream..ctor(String path)