T38-2026 - Notification regarding BIOVIA Foundation, Compose, and Capture 2026 HF2
We are providing this Technical Note to inform you about the release of BIOVIA Foundation, Compose, and Capture 2026 HF2 which includes the following enhancements and fixed defects.
Program
BIOVIA Foundation, Compose, and Capture
Operating System
All supported operating systems
Description
We are providing this Technical Note to inform you about the release of BIOVIA Foundation, Compose, and Capture 2026 HF2 which includes the following enhancements and fixed defects:
Enhancements
This release of BIOVIA Foundation, Compose, and Capture includes the following enhancements.
2026 HF1 Enhancements
Foundation, Compose, and Capture 2026 HF1 includes the following enhancements.
2026 Enhancements
Foundation 2026 includes the following enhancements.
| User Story | Description |
|---|---|
| CAPT-3196 | Global parameters are now available in procedure activities in addition to the previously supported step-level parameters. |
| CAPT-6836 | Review now shows the proper information for Simple Batch task executions. |
| CAPT-7133 | Formulation batch tasks now support interleaved instructions with or without structured process parameters if they are configured in the Formulation Design application. |
| CAPT-9140 | The defined "Wet Percent" of each ingredient action will be displayed in the continuous grid and side panel. |
| CAPT-9585 | Added new "BC: Clean and Sanitize" PET requiring a signed user confirmation that the workspace was cleaned and sanitized before batch start. |
| CAPT-9612 | The system now flags any manual CSV file uploads during Capture execution. Attempting a manual upload will trigger an aRBE exception and automatically activate a “Manual Upload” filter in Review. This is a non-configurable core feature and applies to both Data Acquisition and Procedure activities. Users will see a specific message indicating that the action failed due to a manual upload. |
| CAPT-9680 | In Simple Batch and Procedure executions on 3Dx Platform, the container scan now validates the container first against the planned inventory material ID, and if there is no relationship it triggers a warning and a Material Exception signature. If there is not material ID, validation proceeds against material name and synonym, as before. Container validation in Science Cloud and on-premise is unchanged. |
| CAPT-9853 | If the latest event for an instrument is a failed, unscheduled maintenance event, this causes a Metrology Exception and fails Auto-Review by Exception. |
| DAT-17928 | Updated History pages to display changes to Activity Parameters (planned values, lower/upper limits, etc.) and Task Parameters. |
| DAT-25543 | Study results in the analyze grid that are related to a task can be manually overridden. |
| DAT-27922 | Creating a batch from Formula Design, system now downloads the formula details asynchronously. |
| DAT-28209 | Batch Release & Formulation Batch Plan studies have buttons to allow ad hoc Activities |
| DAT-29281 | System now supports use of Material ID when scanning container IDs. |
| DAT-30152 | Workflow now displays the lifecycle state of the "make Activity" task. |
| DAT-30164 | It is now possible to edit Workflow properties in the Background section when the workflow is In Progress state. |
| DAT-30206 | Message Listener clients can now differentiate between the entity operation that initiated the callback, e.g. insert, update, lifecycle change, or delete. |
| DAT-30341 | Registered materials from Capture are now of type Formulated Materials |
| DAT-30600 | To stay current on the supported versions, the latest versions of Java 11 and Tomcat 9 have been updated. |
| DAT-30633 | Now possible to assign one or more Equipment Classes to an Activity. |
| DAT-30634 | Each instance of High-Value Equipment can be assigned to a specific Hub Group. |
| DAT-30698 | Developers now have an endpoint for disposing a Container |
| DAT-30715 | Simple Batch Activity now supports use of Classification Levels |
| DAT-30835 | Workflow's Background section now displays the Collaborative Space. |
| DAT-30883 | Selected Material Lots and corresponding Specification or Sample Plan Versions expanded to display distinguishing details. |
| DAT-30925 | You can now add conditional values in the extended properties of a Study. |
| DAT-30959 | Stability Workflow now separates the sample pull date from the testing window date. |
| DAT-30966 | Stability Workflow now populates existing OOTB Sample properties Planned Collection Date, Stability Time Point, Stability Temperature (C), Stability Humidity (%RH), and Stability Stress String. |
| DAT-30969 | Added a date range filter and a recursive location-based filter to the Worklist Widget (Samples to Pull Widget) |
| DAT-31211 | You can now add a signature policy to the to the Lifecycle Policy transition: Study > Completed > Reopen Study. |
| DAT-31266 | The Stability Workflow now support manually overriding the task's results. |
| DAT-31355 | Plate object added to support plate-based workflows. |
| DAT-31385 | To streamline the management and submission of plated samples to the testing lab, administrators can now control whether the Plate tab displays in a Task Plan and in which types of Task Plans. This solution integrates directly with a BIOVIA Services–developed Plate tool. |
| DAT-31388 | For efficient execution of high-throughput workflows, you can now assign an Activity to an entire plate of samples. |
| DAT-31879 | A Study Report Protocol has been added to the Database and Application Integration -> Application Integration -> Laboratory -> Operations folder in Pipeline Pilot. |
| PROP-10598 | Process Element Templates can now be edited and saved with their step-level signature settings for Data Entry and Data Verification. |
| PROP-11900 | Material ID is now an available field in procedure activities. This ID can be used for more precise container validation on the 3DEXPERIENCE Platform instead of just material name and synonym. Material ID has no functional purpose for integration with CISPro at this time. |
| PROP-11972 | BIOVIA Compendia process element templates are now included as an improvement to the previously provided standard library content for Compose, supporting use cases in pharmaceutical development. |
| PROP-12553 | Global parameters are now available in procedure activities in addition to the previously supported step-level parameters. |
| PROP-12554 | Global parameters are now available in procedure activities in addition to the previously supported step-level parameters. |
| PROP-12555 | Global parameters are now available in procedure activities in addition to the previously supported step-level parameters. |
| PROP-12830 | Process Element Templates are now managed with respect to collaborative spaces in a manner similar to how activities are. |
| PROP-9797 | Global parameters are now available in procedure activities in addition to the previously supported step-level parameters. |
| SEC-11003 | Metrology due dates can now be scheduled for the end of a week, month, or year. Existing metrology events continue to calculate the next due date based on the date the event was last successfully completed. |
| SEC-11318 | To improve the speed of measurement retrieval and enable retrieval of larger measurements, you can now retrieve a subset of the measurement’s readings. This story applies to measurements based on equipment class readings. |
| SEC-11407 | During data acquisition, the data preview page now has an increased viewing capacity of instrument measurements and performance. * For larger measurement, the data preview page now displays only the columns of data that are needed for the requested parameters in an execution. * The data preview page automatically opens only measurements that can be mapped to the current task. Measurements that are already mapped to tasks do not open. * You can now map samples for measurements up to 150,000 data points, and an error message displays if the measurement exceeds this limit. * You can download a comma-separated value (CSV) file of the full measurement if you need to review additional data. |
| SEC-11424 | Data acquisition tasks with instrument data that was automatically applied can now automatically complete and release. The task automatically completes if each sample has at least one result. Otherwise, it remains in progress. The auto-completed tasks then auto-release if the tasks' lifecycle is configured to allow auto-release, and all the review criteria is met. |
| SEC-11433 | You can now retrieve a subset of the measurement’s readings, which improves the speed of measurement retrieval and enables the retrieval of larger measurements than was previously possible. This story applies to measurements based on data packets. |
| SEC-8453 | A signature can now be required when recording an unscheduled maintenance event or using the Edit button to record a scheduled maintenance event for equipment. This feature is configured by assigning signature policies to the Manual Metrology lifecycle action in the Equipment lifecycle. |
| SEC-8717 | Reference data can now be exported from the entity's Admin and Settings page. One or more reference data can be selected and exported. Administrators may still export all reference data from the Migrations page in Admin and Settings. |
| CAPT-10000 | The Process execution API has been updated for better use in the Pipeline Pilot scripts. |
| CAPT-10097 | The material addition Process Element Template now has Data Entry and Data Verification enabled, so all material addition steps in Simple Batch will requires those signatures as defined by the Lifecycle Policy. |
| CAPT-6507 | When a container is scanned its certification for use in the execution is validated. When the contents of a scanned container do not meet the requirements of the workflow, it triggers a warning and a material exception signature. |
| CAPT-6508 | It is now possible to scan or enter an unregistered container ID, random text, or 'N/A' for the material scan in Capture. If the container ID is not validated in inventory, the user is warned and a material exception signature is presented. |
| DAT-17332 | Additional Hub Notifications created for Retest, Review, Correction Needed, Revert, Task Split, Task Delete, Task Abandon, and Task Plan transitions. |
| DAT-22065 | In a Task Plan and the widget grids, you can now sort the Collaborative Space, Pending Status, and Lifecycle Policy columns. |
| DAT-22837 | Added the ability to configure Signature Policies with a defined signing order, enabling control over approval sequence—for example, requiring QA to sign last. |
| DAT-25671 | Added support for defining exclusive limits (< and >) when configuring Specifications, providing greater flexibility when evaluating them in Workflows. |
| DAT-27846 | Hub configuration switch allows limited use of Request and Split to Task Plan. |
| DAT-27982 | Now possible to configure a signature on Task Plan > Completed > Withdrawn transition |
| DAT-28181 | Enumerate action can be applied to all timepoints, or selectively. By delaying enumeration of later timepoints, you keep the flexibility to adjust the design as needed. |
| DAT-28867 | Given a Workflow with a Specification that includes a string parameter then the parameter displays in the Analyze grid. |
| DAT-30036 | Batch Release workflow enhanced to support additional Candidates. |
| DAT-30056 | Sample Plan option added to support those configurations where not all Activities have samples. |
| DAT-30151 | Add optional rules for how Lifecycle Policy is assigned when creating Samples and Tasks. |
| DAT-30635 | To stay on track, you can now schedule tasks directly onto specific equipment. |
| DAT-31151 | Added an option to physically track Stability inventory as Hub Samples, automatically creating one Hub Sample of EACHES unit per storage condition. |
| DAT-31152 | Enabled editing of the start date for samples and tasks within In Progress Stability Workflows, provided they have not yet been started. |
| DAT-31261 | You can now create a Stability Workflow directly from a Completed or Released Batch Release workflow, which automatically populates the T0 timepoint with the Batch Release results. |
| SEC-11303 | Data acquisition activities can now be configured to allow automatic data acquisition. When an activity is so configured, the system will automatically apply a new measurement to a data acquisition task as long as the measurement contains the task ID (ex: Tnnnn). The task must be in a writable state and not have any manual data entry or manual data acquisitions. This is supported when using class reading equipment commands. |
| CAPT-8532 | Simple Batch tasks now properly support interleaved processing instructions without parameters from Formulation Designer. |
| CAPT-8545 | The material addition steps in Simple Batch are now generated from a backing unit op PET "BC: Direct Weigh", and default to direct weigh for amount collection. |
| CAPT-9276 | The equipment grids no longer display the live equipment status. In the expanded equipment grid, you can now select the !-icon to view the status at the time of use. |
| DAT-24554 | Added support for defining different Sample Types when Sequence Activities create samples, allowing more precise control over sample classification which the CDS Add-in requires. |
| DAT-29259 | Added notifications to alert users when a newer Specification version is available, allowing them to optionally upgrade their In Progress workflow. |
| DAT-29864 | Sample Plan enhanced to allow setting Document ID and Task Lifecycle Policy |
| DAT-29915 | Sequence Activity Tasks can now be batched and executed together. |
| SEC-11302 | The equipment measurement viewer now has a stronger capacity to handle larger measurements. * You can now view data points of up to 150,000. * You can download comma-separated value (CSV) files of measurements larger than 150,000 data points. You can view these in Microsoft Excel or other CSV-viewing applications. |
| DAT-23627 | Added support for redesigning an approved Stability Study Workflow even after execution has begun. |
| SEC-11174 | The integration gateway was updated to a newer release of Node.js. |
| DAT-29197 | The Grails Framework has been updated to version 5 to stay current. |
Fixed Defects
This release of BIOVIA Foundation, Compose, and Capture includes the following fixed defects.
2026 HF2 Fixed Defects
Foundation 2026 HF2 includes the following fixed defects.
| Defect | Description |
|---|---|
| DAT-33195 | Fixed a rare database migration issue when upgrading from 2024 SP1 HFx to 2026 HF1. |
| DAT-33224 | It is no longer necessary to include the "filter" section in the subscriber JSON necessary for triggering subscriber protocols after upgrading from 2024 SP1 HFx. |
2026 HF1 Fixed Defects
Foundation 2026 HF1 includes the following fixed defects.
Resolution
BIOVIA Foundation, Compose, and Capture 2026 HF2 was released in January 2026 and is available for download at https://software.3ds.com under BIOVIA products:
Product line: Lab, Scientific and Content Solutions
Release: BIOVIA 2026
Level: BIOVIA 2026 Golden
Fixes for this level: BIOVIA 2026 Golden HF1
How to contact BIOVIA Support
If you have any questions, please contact BIOVIA Support.
Need Assistance?
Our support team is here to help you make the most of our software. Whether you have a question, encounter an issue, or need guidance, we've got your back.